2.1
Knee fusion with the TK-IIizarov Fixator。
2.1
Knee fusion with the TK-IIizarov Fixator.
2.2
Knee fusion with the Micro Movement Fixator (D100 series). In poor quality bone, two fixators can be used, one applied anteriorly as shown, and one laterally.
Use of HA-coated screws is recommended.
2.2
Knee fusion with the Micro Movement Fixator (D100 series). In poor quality bone, two fixators can be used, one applied anteriorly as shown, and one laterally.
Use of HA-coated screws is recommended.
2.2
(a) Diaphyseal deformity of femur; D100 series fixator in place.
(b) Osteotomy and correction of deformity.
Use of HA-coated screws is recommended.
2.2
(a) Diaphyseal deformity of femur; D100 series fixator in place.
(b) Osteotomy and correction of deformity.
Use of HA-coated screws is recommended.
1.13
The T-Clamp or B.G.T Clamp can be used as an alternative to Metaphyseal Clamp.
1.13
The T-Clamp or B.G.T Clamp can be used as an alternative to Metaphyseal Clamp.
6.1
Bone transport to fill a defect in the second metacarpal; D500 series. Arrow shows the direction of movement of the middle clamp.
6.1
Bone transport to fill a defect in the second metacarpal; D500 series. Arrow shows the direction of movement of the middle clamp.
1.1
Distal tibial articular fracture stabilized using the TK-IIizarov Fixator with rapid adjust struts.
1.1
Distal tibial articular fracture stabilized using the TK-IIizarov Fixator with rapid adjust struts.
1.2
Distal tibial articular fracture stabilized using the Sheffield Ring Fixator with rings connected by Threaded Bars. One wire-bearing ring for the distal fracture and one ring with the Sheffield Clamp for the diaphyseal screws.
In severe pilon fractures, a foot ring can be added with hinges to stabilize the ankle joint and mobilize it when possible.
1.2
Distal tibial articular fracture stabilized using the Sheffield Ring Fixator with rings connected by Threaded Bars. One wire-bearing ring for the distal fracture and one ring with the Sheffield Clamp for the diaphyseal screws.
In severe pilon fractures, a foot ring can be added with hinges to stabilize the ankle joint and mobilize it when possible.
1.3
Distal articular fracture treated with Radiolucent Hybrid Fixator (H800 series).
1.3
Distal articular fracture treated with Radiolucent Hybrid Fixator (H800 series).
1.4
Distal tibial articular fracture treated with Radiolucent Ankle Fixator (D120 series).
1.4
Distal tibial articular fracture treated with Radiolucent Ankle Fixator (D120 series).
2.1
Ankle fusion (tibio-talar).
Micro Movement Fixator (D100 series) with B.G.T Clamp distally for screws in talus (a, a1 in inset). The Straight Clamp may also be used distally, with one screw in the talus and one screw in the calcaneus (b, b1 in inset) for subtalar/tibio-talar double fusion.
2.1
Ankle fusion (tibio-talar).
Micro Movement Fixator (D100 series) with B.G.T Clamp distally for screws in talus (a, a1 in inset). The Straight Clamp may also be used distally, with one screw in the talus and one screw in the calcaneus (b, b1 in inset) for subtalar/tibio-talar double fusion.
1.1
(a) Fracture and/or dislocation of the elbow.
(b) Elbow fixator in place with Extended Range Clamp for ulnar screws.
Caution: radial nerve.
1.1
(a) Fracture and/or dislocation of the elbow.
(b) Elbow fixator in place with Extended Range Clamp for ulnar screws.
Caution: radial nerve.
2.1
Use of the Elbow Fixator as an interim measure to maintain movement following removal of an infected prosthesis and prior to joint replacement.
Caution: radial nerve.
2.1
Use of the Elbow Fixator as an interim measure to maintain movement following removal of an infected prosthesis and prior to joint replacement.
Caution: radial nerve.